Thermal mass (Cth, also called heat capacity) is the capacity of a body to store heat, and is calculated as the product of mass the body m and the specific heat capacity for the material cp, and typically is measured in units of J/°C or J/K (which are equivalent). Thermal mass as a concept is most frequently applied in the field of building design. In this context, thermal mass provides 'inertia' against temperature fluctuations. For example, for a building, when outside temperatures are fluctuating throughout the day, a large thermal mass within the insulated portion of the house can serve to 'flatten out' the daily temperature fluctuations, since the thermal mass will absorb heat when the surroundings are hotter than the mass, and give heat back when the surroundings are cooler. Thermal mass is effective in improving building comfort in any place that experiences these types of daily temperature fluctuations -- both in winter as well as in summer. When used well and combined with passive solar design, thermal mass can play an important role in major reductions to energy use in active heating and cooling systems and hence the reduction of greenhouse gas emissions due to fossil fuel burning in power stations.
Properties required for good thermal massIdeal materials for thermal mass are those materials that have:
Any solid, liquid, or gas that has mass will have some thermal mass. A common misconception is that only concrete or earth soil has thermal mass; even air has thermal mass (although very little.) A useful table of volumetric heat capacity for building materials is available from yourhome.gov.au (but note that their definition of thermal mass is slightly different). Use of thermal mass in different climatesThe correct use and application of thermal mass is dependent on the prevailing climate in a district. Temperate / Cold Temperate climatesThermal mass is ideally placed within the building and situated where it still can be exposed to winter sunlight (via windows) but insulated from heat loss. The thermal mass is warmed passively by the sun or additionally by internal heating systems during the day. Heat stored in the mass is then released back into the interior during the night. It is essential that it be used in conjunction with the standard principles of passive solar design. Any form of thermal mass can be used. A concrete slab foundation either left exposed or covered with conductive materials e.g. tiles; is one easy solution. Another novel method is to place the masonry facade of a timber-framed house on the inside ('reverse-brick veneer'). Thermal mass in this situation is best applied over a large area rather than in large volumes or thicknesses. 7.5-10 cm (3-4") is often adequate. Since the most important source of heat is from the sun, the ratio of glazing to thermal mass is an important factor to consider. Various formulas have been devised to determine this.1 As a general rule, additional solar-exposed thermal mass needs to applied in a ratio from 6-8:1 for any area of north facing (Southern Hemisphere)(south facing, Northern Hemisphere) glazing above 7% of the total floor area. e.g. a 200 sqm house with 20sqm of north facing glazing has 10% of glazing by total floor area. 6sqm of that glazing will require additional thermal mass. Therefore, 36-48 sqm of solar-exposed thermal mass is required. The exact requirements vary from climate to climate. Hot, arid climates (e.g. desert)This is a classical use of thermal mass. Examples include adobe or rammed earth houses. Its function is highly dependent on marked diurnal temperature variations. The wall predominantly acts to retard heat flow from the exterior to the interior during the day. The high volumetric heat capacity and thickness prevents heat from reaching the inner surface. When temperatures fall at night, the walls re-radiate the heat back into the night sky. In this application it is important for such walls to be massive to prevent the ingress of heat into the interior. Hot humid climates (e.g. sub-tropical/tropical)The use of thermal mass is the most challenging in this environment where night temperatures remain elevated. Its use is primarily as a temporary heat sink. However, it needs to be strategically located to prevent overheating. It should be placed in an area that is not directly exposed to solar gain and also allow adequate ventilation at night to carry away stored energy without increasing internal temperatures any further. If to be used at all it should be used in judicious amounts and again not in large thicknesses. Materials commonly used for thermal mass
Seasonal energy storageIf enough mass is used it can create a seasonal advantage. That is it can heat in the winter and cool in the summer. This is sometimes called "Passive annual heat storage or PAHS". The PAHS system has been successfully used at 7000 ft. in Colorado and in a number of homes in Montana.citation needed References
See also
|
| prawdopodobnie najlepsze forum dyskusyjne • Smutne • Smutne • Najtańsze ogrzewanie dla każdego • pomiary pól • Deszczownie • pastwiska • gospodarstwa rolne • Angelika • Czesława • Diana • Angelika • Berta • Blanka • Alicja All Right Reserved © 2007, Designed by Stylish Blog. |